Data Centre Monitoring in Ireland From One Comms Room to a Full Data Hall

Rack temperature and humidity, water and coolant leaks, power, doors and smoke, watched around the clock and alerted the moment something drifts. TITAN IoT supplies HW Group monitoring across an estate of rooms, staged in Galway so every unit arrives ready to connect.

Hospitals, county councils, pharma plants and colocation halls all run rooms full of servers. Start with one room, prove the alerts, then roll it out.

Data centre hall with rows of server racks monitored for temperature, leaks and access
Appointed Irish DistributorHW Group refers Irish enquiries to TITAN
Alerts Through an OutageLTE, battery backup and SMS when the LAN or power drops
Into Your Own SystemsSNMP, Modbus TCP, MQTT and XML, or the SensDesk cloud
Staged in GalwayConfigured and tested before it ships
The Essentials

What Is Data Centre Monitoring?

Data centre monitoring is hardware that watches the environment around your IT equipment: rack temperature and humidity, water and coolant leaks, mains and UPS power, doors, smoke and fans. It alerts by email, SMS, SNMP trap or a local siren when a reading crosses a warning or critical level, so a cooling failure or leak is caught before equipment is damaged.

It watches the room, not the servers. That is why it still reports when the IT systems themselves are struggling.

Data centre server racks with environmental and access monitoring
For Estates of Rooms

Many Rooms, One Standard, One View.

The rollout we plan for is the estate: a health network with a comms room in every building, a council with server rooms across the county, a pharma site with IT rooms beside validated production, a colocation hall with hundreds of racks. HW Group report over 150,000 of their monitoring devices sold worldwide, and the same units scale from one rack to the whole estate.

The same unit in every room

One monitoring standard, configured once and staged in Galway for each site.

Two alarm levels per sensor

Warning goes to email, critical goes to SMS, a call or a siren, to the right people per site.

Every room on one dashboard

SNMP into your own NMS, or every site in SensDesk with reports and history.

Grows a sensor at a time

Up to 100 sensors per rack unit on the Perseus 150, added as the room fills up.

What It Watches

Every Way a Room Fails Quietly

Each of these is invisible until it isn’t, and each one is a sensor on the same monitoring unit.

HW Group monitoring units and sensors watching temperature, leaks and access across server racks

Rack temperature & humidity

Probes at rack inlet and outlet catch a failing cooling unit while there is still time to act.

Water and coolant leaks

Sensing cable under the floor, along pipe runs and around cooling units.

Power and UPS

Mains presence on each feed, plus UPS, meters and air-con read over Modbus RTU.

Doors and access

Door contacts on rooms and rack doors, alerting out of hours or when left open.

Smoke and fans

Smoke detectors and fan-failure inputs on the same unit as the probes.

Local action

Relay outputs drive a siren, beacon or ventilation when a critical level is reached.

Liquid coolingHW Group’s sensing cable detects water, ethylene glycol and other conductive liquids anywhere along its length, from the first few drops. That covers chilled-water pipework and glycol cooling loops as well as the raised floor. The WLD-Location cable goes further and reports where along the run the leak is.
Two Ways to Run It

Into Your Own Systems, or the SensDesk Cloud

Both are normal, and you can change your mind later. The hardware is the same either way.

Feed Your Own Network

  • SNMP, Modbus TCP, MQTT and XML straight from the device
  • Into your existing NMS, BMS, DCIM or SCADA
  • Email, SNMP trap and relay alerts from the unit itself
  • No cloud and no subscription needed, and no lock-in
HW Group SensDesk cloud portal showing monitored rooms and sensors

Use the SensDesk Cloud

  • HW Group’s own portal: every room and site on one dashboard
  • SMS and voice-call alerts, history, scheduled reports
  • Free HWg-cloud tier for smaller setups
  • Can also run on-premise for closed networks
When Everything Else Is Down

Alerts That Still Get Out

The worst time to lose monitoring is during the outage it should be reporting. HW Group give you three ways to keep the alert path independent of the site network and power.

Cellular backup

The Perseus 145 monitors and sends SMS over its own LTE. The rack-mount Perseus 155 uses the LAN and switches to LTE when the LAN drops. Ask us for the 155.

Battery backup

The Ares 12 LTE carries an internal battery for up to 24 hours and keeps reporting over LTE when the mains fails.

SMS gateway

HW Group’s LTE SMS gateway sends text alerts for the network-connected units in a room, with no dependence on email or the internet. Ask us to spec it.

HW Group Perseus Monitoring 145 with LTE for independent SMS alerting
Remote Reboot & Power Metering

Reboot It From Your Desk

The HW Group units tell you a room has a problem. A NETIO networked PDU lets you act on it: power-cycle a hung switch, router or server from your desk and see what each outlet is drawing, with no site visit for a frozen device.

Restart any outlet remotely

Switch each outlet off, on or through a short restart from a browser, the NETIO app or your own system.

Automatic restart

A ping watchdog power-cycles a device that stops answering on the network, without anyone having to notice first.

Metering on every outlet

The 4KS and 8KS measure current, power and energy per outlet to better than 1%, so overloaded circuits show up before a breaker trips.

The same systems as the monitoring

SNMP, Modbus TCP, MQTT and JSON from the PDU itself, and NETIO lists HW Group’s Perseus platform among its integration partners.

NETIO PowerPDU 4PS 4-outlet IEC C13 switched PDU for remote reboot

NETIO

PowerPDU 4PS

Four switched IEC C13 outlets for remote reboot, without metering. Ping watchdog and a power-up delay per outlet. Fits 1U with the RM1 bracket.

NETIO PowerPDU 4KS 4-outlet IEC C13 PDU with per-outlet power metering

NETIO

PowerPDU 4KS

Four IEC C13 outlets, each switched and metered. Ping and power-consumption watchdogs, plus a digital input. Fits 1U with the RM1 bracket.

NETIO PowerPDU 8KS 1U rack PDU with 8 metered IEC C13 outlets

NETIO

PowerPDU 8KS

Eight IEC C13 outlets in a 1U rack chassis, each switched and metered, on a 16 A C20 input. Per-outlet energy supports billing power back per device.

Supplied through TITANNETIO PDUs are supplied through TITAN alongside the HW Group monitoring. Ask us for pricing and lead times, and we’ll match the PDU to the rack.
The Kit

HW Group Monitoring, Matched to the Room

A monitoring unit for the room or rack, sensors for what it needs to see, and the leak detection that suits the floor and the cooling.

HW Group Perseus Monitoring 150 1U rack-mount data centre monitoring unit

HW Group

Perseus Monitoring 150

1U rack unit: 8 sensor ports, 16 dry-contact inputs, a leak zone and 4 relays. Up to 100 sensors, Modbus RTU for UPS and air-con. PoE, 9–30 V or -48 V.

HW Group Perseus Monitoring 145 LTE monitoring unit

HW Group

Perseus Monitoring 145

Monitors over its own LTE, independent of the site network, with SMS and email direct from the unit and a relay for a local siren. One per site.

HW Group Perseus Industrial 310 DIN rail unit with leak-locating port

HW Group

Perseus Industrial 310 / 315

DIN rail unit for plant rooms and cooling plant, with a leak-locating port, Modbus RTU and BACnet. The 315 adds LTE with SMS.

HW Group Ares 12 LTE monitoring unit with internal backup battery

HW Group

Ares 12 LTE

LTE monitoring unit with an internal battery for up to 24 hours, 14 sensor inputs and a large data log. Keeps reporting through a power cut.

HW Group STE2 r2 Ethernet and Wi-Fi monitoring unit for a comms room

HW Group

STE2 r2

Compact Ethernet and Wi-Fi unit for a single comms room or cabinet: temperature, humidity and door contact, with email and SNMP alerts.

HW Group WLD-ECHO standalone two-zone water leak detector

HW Group

WLD-ECHO Leak Detector

Two leak zones and up to 185 m of sensing cable, with a sounder, visual alarm and relay into your alarm panel or BMS. Battery or 12 V.

HW Group WLD-Location Cable L leak-locating sensing cable

HW Group

WLD-Location Cable L

Sensing cable that reports where the leak is, to within 4% of the run. Up to 100 m per zone on a Perseus Industrial 310 or 315.

HW Group WLD2 four-zone water leak detector

HW Group

WLD2 Leak Detector

Four leak zones on one Ethernet unit, for raised floors split into areas so the alert tells you which part of the room is wet.

HW Group HTemp HomeBox temperature and humidity probe

HW Group

HTemp HomeBox Probe

The standard temperature and humidity probe for rack inlets and rooms. Plugs into the RJ11 sensor ports on the units above.

Not listed hereDoor contacts, smoke detectors, power-presence sensors, the Perseus 155 and the LTE SMS gateway are all part of the HW Group range and available through us. Tell us what needs watching and we’ll match the sensor.
How It Works

Monitor One Room, Then Roll Out

1

Pilot one room

We spec and stage a monitoring unit, sensors and leak cable for a single room or rack.

2

Prove the alerts

Trigger a test alarm and confirm warning and critical alerts reach the right people, or your own system.

3

Stage the estate

The proven setup is staged in Galway per room and shipped ready to connect.

4

Watch every room

Every room in your NMS or on SensDesk, with sensors added as racks fill up.

Where It Fits

Any Room Where Servers Can’t Go Down

A data centre is not only a data hall. These are the rooms the same HW Group kit is made for.

Colocation & Data Halls

Rack-by-rack temperature, leak cable under the floor and along cooling loops, all fed into your DCIM over SNMP or Modbus TCP.

Perseus 150 · WLD-Location Cable L · HTemp

Hospitals & Health Networks

A comms room in every building, each with the same unit and an LTE alert path that works when the hospital network is under strain.

Perseus 145 · HTemp · door contacts

County Councils & Public Buildings

Server rooms spread across a county, monitored to one standard and visible on one dashboard for a small IT team.

STE2 r2 · Perseus 150 · SensDesk

Pharma & Manufacturing Sites

IT rooms beside production, where history and scheduled reports matter as much as the alert itself.

Perseus 150 · SensDesk reports

Cooling & Plant Rooms

Chillers, CRAC units and glycol pipework, with leak location along the run and Modbus readings from the plant.

Perseus Industrial 310 · WLD-Location Cable L

Single Comms Rooms

One room in an office or school, covered with a compact unit, a probe, a door contact and a standalone leak alarm.

STE2 r2 · WLD-ECHO

Related

Go Further

Server Room Monitoring

The smaller version: one room, three sizes of answer.

Water Leak Detection

Every leak option, from spot sensors to leak-locating cable.

Environmental Monitoring

The full range of monitoring units and sensors.

Internet Backup & 4G Failover

Keep the site online when the fixed line goes down.

FAQ

Data Centre Monitoring Questions, Answered

What is data centre monitoring?

Data centre monitoring is hardware that watches the environment around IT equipment: rack temperature and humidity, water and coolant leaks, power, doors, smoke and fans. It alerts by email, SMS, SNMP trap or a local siren when a reading crosses a warning or critical level, so a cooling failure or leak is caught before servers and network equipment are damaged.

Is it only for large data centres?

No. The same HW Group units cover a single comms room in an office, server rooms in a hospital, county council or pharma plant, and racks in a colocation hall. A compact STE2 suits one room; the rack-mount Perseus 150 takes up to 100 sensors. Most estates use one standard unit in every room so setup and support stay identical.

Can it detect glycol leaks from liquid cooling?

Yes. HW Group state that their sensing cable detects water, ethylene glycol and other conductive liquids anywhere along its length, from the first few drops. That covers chilled-water pipework and glycol cooling loops as well as raised floors. The WLD-Location cable also reports where along the run the leak is, to within about 4% of the cable length.

What happens if the power or network goes down?

Choose a unit with its own alert path. The Perseus 145 monitors and sends SMS over LTE, independent of the site network. The Ares 12 LTE has an internal battery for up to 24 hours, so it keeps reporting through a power cut. HW Group’s LTE SMS gateway sends text alerts for network-connected units without relying on email or the internet.

Can it feed our existing BMS, NMS or DCIM?

Yes. The Perseus units talk SNMP, Modbus TCP, MQTT and XML directly, and the Perseus Industrial range adds BACnet. Readings and alarms go straight into the system you already run, with no cloud and no subscription required. Perseus units can also read third-party UPS, air-con and electricity meters over Modbus RTU and pass those values on too.

Do we need the SensDesk cloud?

No, it’s optional. Many sites run the units entirely on their own network. SensDesk is HW Group’s portal for customers who want a hosted dashboard: every room on one screen, SMS and voice-call alerts, history and scheduled reports. A free HWg-cloud tier suits smaller setups, and SensDesk can also run on-premise for closed networks.

How many sensors can one rack unit take?

The Perseus Monitoring 150 is a 1U rack unit with 8 sensor ports, 16 dry-contact inputs, one leak-detection zone and 4 relay outputs. HW Group rate it for up to 100 sensors and 1,000 values, including third-party meters over Modbus RTU. It runs from PoE, 9 to 30 V or -48 V, so it fits standard data centre power.

Can we restart equipment remotely?

Yes. A NETIO networked PDU, supplied through TITAN, switches each outlet over the network, so a hung switch, router or server can be power-cycled from your desk, or automatically when it stops answering a ping. The 4KS and 8KS also meter every outlet, and all three talk SNMP, Modbus TCP and MQTT alongside the HW Group units.

Can we pilot one room before rolling out?

Yes, and we recommend it. We spec and stage a monitoring unit, probes and leak cable for one room so your team can trigger a test alarm and confirm alerts reach the right people or your own system. Once the pilot works, the same configuration is staged in Galway for every other room and shipped ready to connect.

Tell Us About Your Rooms

How many rooms, where they are and what worries you most. We’ll spec the HW Group kit, stage a pilot in Galway and plan the rollout from there.